windows – 如何设置NTP客户端与NTP服务器同步的频繁周期

前端之家收集整理的这篇文章主要介绍了windows – 如何设置NTP客户端与NTP服务器同步的频繁周期前端之家小编觉得挺不错的,现在分享给大家,也给大家做个参考。
我为我的DC设置了一个NTP客户端,以便与time. windows.com同步时间,但我希望它每天至少两次查询NTP服务器.我通过注册表进行了所有更改,是否有一个我可以修改的期间注册表以及如何?
您有注册表值列表 here.

参考此处,尝试设置以下值:

SpecialPollInterval :
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\TimeProviders\NtpClient

说明:

Version : Windows XP,Windows Vista,Windows Server 2003,and Windows Server 2008
This entry specifies the special poll interval in seconds for manual peers. When the SpecialInterval 0x1 flag is enabled (see next key : NtpServer),W32Time uses this poll interval instead of a poll interval determine by the operating system. The default value on domain members is 3,600 (1 hour). The default value on stand-alone clients and servers is 604,800 (7 days).

NtpServer
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\Parameters

说明:

Version : Windows Server 2003 and Windows Server 2008
This entry specifies a space-delimited list of peers from which a computer obtains time stamps,consisting of one or more DNS names or IP addresses per line. Each DNS name or IP address listed must be unique. Computers connected to a domain must synchronize with a more reliable time source,such as the official U.S. time clock.
0x01 SpecialInterval
There is no default value for this registry entry on domain members. The default value on stand-alone clients and servers is time.windows.com,0x1.

UpdateInterval :
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\Config

说明:

Version : Windows XP,and Windows Server 2008
This entry specifies the number of clock ticks between phase correction adjustments. The default value for domain controllers is 100. The default value for domain members is 30,000. The default value for stand-alone clients and servers is 360,000.

MinPollInterval :
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\W32Time\Config

说明:

Version : Windows XP,and Windows Server 2008 This entry specifies the smallest interval,in log2 seconds,allowed for the system polling interval. Note that while a system does not request samples more frequently than this,a provider can produce samples at times other than the scheduled interval. The default value for domain controllers is 6. The default value for domain members is 10. The default value for stand-alone clients and servers is 10.

原文链接:https://www.f2er.com/windows/370455.html