我在这里没有想法.我们有一台2008服务器,通过“意外关机”事件,每天在完全随机的时间内重启2-3次.没有转储,没有事件导致它就像它失去了电力然后重新上线.我对电源进行了诊断,并持续供电数月.此外,处理器的温度最高可达40摄氏度.任何人都有任何想法如何弄清楚为什么这一直在重新启动?这是一个DMZed Web服务器,所以它不会做太多的过程.以下是规格:
Host Name: ~~~ OS Name: Microsoft Windows Server 2008 R2 Standard OS Version: 6.1.7600 N/A Build 7600 OS Manufacturer: Microsoft Corporation OS Configuration: Standalone Server OS Build Type: Multiprocessor Free Registered Owner: Windows User Registered Organization: Product ID: ~~~ Original Install Date: 5/27/2010,4:25:47 PM System Boot Time: 2/14/2011,5:35:01 PM System Manufacturer: HP System Model: ProLiant DL380 G6 System Type: x64-based PC Processor(s): 1 Processor(s) Installed. [01]: Intel64 Family 6 Model 26 Stepping 5 GenuineIntel ~1586 Mhz BIOS Version: HP P62,8/16/2010 Windows Directory: C:\Windows System Directory: C:\Windows\system32 Boot Device: \Device\HarddiskVolume1 System Locale: en-us;English (United States) Input Locale: en-us;English (United States) Time Zone: (UTC-05:00) Eastern Time (US & Canada) Total Physical Memory: 4,086 MB Available Physical Memory: 2,775 MB Virtual Memory: Max Size: 8,170 MB Virtual Memory: Available: 6,691 MB Virtual Memory: In Use: 1,479 MB Page File Location(s): C:\pagefile.sys
特定运行的HP ProLiant DL380 G6服务器与电源管理单元相连,存在一个小问题.
原文链接:https://www.f2er.com/windows/367552.html请参阅:
http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&objectID=c01955503
使用版本号早于“0S”的系统板配置的有限数量的基于ProLiant DL380 G6的服务器和StorageWorks产品(在下面的“范围”部分中列出)可能会意外重启.在重新引导期间,以下消息将记录在Integrated Lights-Out 2(iLO 2)事件日志中:
服务器重置,服务器电源已删除,服务器电源已恢复
发生这种情况时,不会记录任何硬件错误,集成管理日志(IML)中不会捕获任何事件,系统也不会执行自动服务器恢复(ASR);但是,操作系统日志将指示发生意外重新启动.
范围
数量有限的ProLiant DL380 G6和ProLiant DL380 G6操作符级服务器,配置有修订级别低于0S的系统板,于2009年11月16日之前发货,序列号早于XXX 947 XXXX.
这影响了我安装的许多第一批DL380 G6系统.它需要在上面的链接上更新固件并关闭电源,拔下电源线,然后打开电源进行激活.根据通知检查序列号范围.