基于.NET的安装项目在安装时失败

前端之家收集整理的这篇文章主要介绍了基于.NET的安装项目在安装时失败前端之家小编觉得挺不错的,现在分享给大家,也给大家做个参考。
我使用 Visual Studio 2008创建了一个安装项目.在另一台机器上安装时,出现以下错误

The installer was interrupted before
MyApplication could be installed. You
need to restart the installer to try
again.

我该如何解决这个问题?

日志文件显示以下内容.

MSI (s) (D8:20) [14:06:01:020]: Executing op: ComponentUnregister(ComponentId={533BAFA2-3A54-B4D7-B625-38EB0DB9BBB7},ProductKey={B10107EF-3C57-451E-9080-40FB1F4A8B95},BinaryType=0,)
MSI (s) (D8:20) [14:06:01:020]: Executing op: ComponentUnregister(ComponentId={B55DBDAF-0BCB-061A-9EA2-5AC798377ABA},)
MSI (s) (D8:20) [14:06:01:020]: Executing op: End(Checksum=0,ProgressTotalHDWord=0,ProgressTotalLDWord=0)
MSI (s) (D8:20) [14:06:01:020]: Error in rollback skipped.  Return: 5
MSI (s) (D8:20) [14:06:01:030]: No System Restore sequence number for this installation.
MSI (s) (D8:20) [14:06:01:030]: Unlocking Server
MSI (s) (D8:20) [14:06:01:030]: PROPERTY CHANGE: Deleting UpdateStarted property. Its current value is '1'.
Action ended 14:06:01: INSTALL. Return value 3.
MSI (s) (D8:20) [14:06:01:060]: MainEngineThread is returning 1603
MSI (s) (D8:40) [14:06:01:060]: Destroying RemoteAPI object.
MSI (s) (D8:B8) [14:06:01:060]: Custom Action Manager thread ending.
MSI (c) (10:80) [14:06:01:130]: Back from server. Return value: 1603
MSI (c) (10:80) [14:06:01:140]: Decrementing counter to disable shutdown. If counter >= 0,shutdown will be denied.  Counter after decrement: -1
MSI (c) (10:80) [14:06:01:140]: PROPERTY CHANGE: Deleting SECONDSEQUENCE property. Its current value is '1'.
Action ended 14:06:01: ExecuteAction. Return value 3.
MSI (c) (10:80) [14:06:01:150]: Doing action: FatalErrorForm
Action start 14:06:01: FatalErrorForm.
DEBUG: Error 2826:  Control Line1 on dialog FatalErrorForm extends beyond the boundaries of the dialog to the right by 3 pixels
The installer has encountered an unexpected error installing this package. This may indicate a problem with this package. The error code is 2826. The arguments are: FatalErrorForm,Line1,to the right
DEBUG: Error 2826:  Control Line2 on dialog FatalErrorForm extends beyond the boundaries of the dialog to the right by 3 pixels
The installer has encountered an unexpected error installing this package. This may indicate a problem with this package. The error code is 2826. The arguments are: FatalErrorForm,Line2,to the right
DEBUG: Error 2826:  Control BannerBmp on dialog FatalErrorForm extends beyond the boundaries of the dialog to the right by 3 pixels
The installer has encountered an unexpected error installing this package. This may indicate a problem with this package. The error code is 2826. The arguments are: FatalErrorForm,BannerBmp,to the right
Action ended 14:06:04: FatalErrorForm. Return value 1.
Action ended 14:06:04: INSTALL. Return value 3.
MSI (c) (10:80) [14:06:04:475]: Destroying RemoteAPI object.
MSI (c) (10:F4) [14:06:04:485]: Custom Action Manager thread ending.
=== Logging stopped: 5/12/2009  14:06:04 ===
MSI (c) (10:80) [14:06:04:495]: Note: 1: 1708 
MSI (c) (10:80) [14:06:04:505]: Product: CMS -- Installation Failed.

MSI (c) (10:80) [14:06:04:515]: Grabbed execution mutex.
MSI (c) (10:80) [14:06:04:525]: Cleaning up uninstalled install packages,if any exist
MSI (c) (10:80) [14:06:04:545]: MainEngineThread is returning 1603
=== Verbose logging stopped: 5/12/2009  14:06:04 ===

`

尝试通过命令行安装以获取日志文件.那应该包含错误信息.

msiexec / i program_name / lv mylogfile.log

您可以使用Wilogutl更轻松地分析日志文件.

原文链接:https://www.f2er.com/windows/364928.html

猜你在找的Windows相关文章