前端之家收集整理的这篇文章主要介绍了ubuntu – lm-sensors电压报警,可以安全忽略?前端之家小编觉得挺不错的,现在分享给大家,也给大家做个参考。
我正在构建一个小型NAS服务器,主板是 Intel D2700MUD(无风扇),PSU是“Ace Outburst 480W”.安装Ubuntu Server后,我安装了lm-sensors.输出
coretemp-isa-0000
Adapter: ISA adapter
Core 0:       +38.0 C  (high = +80.0 C,crit = +100.0 C)
Core 1:       +33.0 C  (high = +80.0 C,crit = +100.0 C)

w83627dhg-isa-0290
Adapter: ISA adapter
Vcore:        +1.22 V  (min =  +0.00 V,max =  +1.74 V)
in1:          +1.02 V  (min =  +0.58 V,max =  +1.06 V)
AVCC:         +3.38 V  (min =  +2.78 V,max =  +0.64 V)  ALARM
+3.3V:        +3.38 V  (min =  +0.82 V,max =  +0.59 V)  ALARM
in4:          +1.03 V  (min =  +1.25 V,max =  +0.42 V)  ALARM
in5:          +1.52 V  (min =  +1.78 V,max =  +0.51 V)  ALARM
in6:          +1.02 V  (min =  +0.16 V,max =  +0.10 V)  ALARM
3VSB:         +3.34 V  (min =  +1.65 V,max =  +1.15 V)  ALARM
Vbat:         +3.22 V  (min =  +2.34 V,max =  +1.02 V)  ALARM
fan1:           0 RPM  (min = 2109 RPM,div = 128)  ALARM
fan2:           0 RPM  (min =  458 RPM,div = 128)  ALARM
fan3:           0 RPM  (min =  234 RPM,div = 128)  ALARM
fan4:           0 RPM  (min =  659 RPM,div = 128)  ALARM
fan5:           0 RPM  (min = 5273 RPM,div = 128)  ALARM
temp1:        +44.0 C  (high = +35.0 C,hyst = +32.0 C)  ALARM  sensor = diode
temp2:       +110.5 C  (high = +80.0 C,hyst = +75.0 C)  ALARM  sensor = diode
temp3:        +30.5 C  (high = +80.0 C,hyst = +75.0 C)  sensor = diode
cpu0_vid:    +2.050 V

我是否需要担心in4,in5,in6 ..或temp1 / temp2的电压警报?

限制未正确配置,它们可能是默认值或来自其他一些板.例如:

3.3V:3.38 V(最小值= 0.82 V,最大值= 0.59 V)

对于3.3V电源而言看起来合理,但限制完全没有,并且最大值低于最小值!

temp2看起来有点令人担忧,但这也可能是一个配置错误的传感器.