我正在构建一个小型NAS服务器,主板是
Intel D2700MUD(无风扇),PSU是“Ace Outburst 480W”.安装Ubuntu Server后,我安装了lm-sensors.输出:
coretemp-isa-0000 Adapter: ISA adapter Core 0: +38.0 C (high = +80.0 C,crit = +100.0 C) Core 1: +33.0 C (high = +80.0 C,crit = +100.0 C) w83627dhg-isa-0290 Adapter: ISA adapter Vcore: +1.22 V (min = +0.00 V,max = +1.74 V) in1: +1.02 V (min = +0.58 V,max = +1.06 V) AVCC: +3.38 V (min = +2.78 V,max = +0.64 V) ALARM +3.3V: +3.38 V (min = +0.82 V,max = +0.59 V) ALARM in4: +1.03 V (min = +1.25 V,max = +0.42 V) ALARM in5: +1.52 V (min = +1.78 V,max = +0.51 V) ALARM in6: +1.02 V (min = +0.16 V,max = +0.10 V) ALARM 3VSB: +3.34 V (min = +1.65 V,max = +1.15 V) ALARM Vbat: +3.22 V (min = +2.34 V,max = +1.02 V) ALARM fan1: 0 RPM (min = 2109 RPM,div = 128) ALARM fan2: 0 RPM (min = 458 RPM,div = 128) ALARM fan3: 0 RPM (min = 234 RPM,div = 128) ALARM fan4: 0 RPM (min = 659 RPM,div = 128) ALARM fan5: 0 RPM (min = 5273 RPM,div = 128) ALARM temp1: +44.0 C (high = +35.0 C,hyst = +32.0 C) ALARM sensor = diode temp2: +110.5 C (high = +80.0 C,hyst = +75.0 C) ALARM sensor = diode temp3: +30.5 C (high = +80.0 C,hyst = +75.0 C) sensor = diode cpu0_vid: +2.050 V
我是否需要担心in4,in5,in6 ..或temp1 / temp2的电压警报?
限制未正确配置,它们可能是默认值或来自其他一些板.例如:
3.3V:3.38 V(最小值= 0.82 V,最大值= 0.59 V)
对于3.3V电源而言看起来合理,但限制完全没有,并且最大值低于最小值!
temp2看起来有点令人担忧,但这也可能是一个配置错误的传感器.